INSTALLATION
This section covers unpacking and inspection, selecting location, installing Unit, preparing for operation, and
operation.
UNPACKING AND INSPECTION
NOTE: The Unit was thoroughly inspected before leaving the factory and the carrier has accepted and
signed for it. Any damage or irregularities should be noted at the time of delivery (or not later than 15
days from date of delivery) and immediately reported to the delivering carrier. Request a written inspec-
tion report from Claims Inspector to substantiate any necessary claim. File claim with the delivering
carrier, not with IMI Cornelius Inc.
1. Locate the dispenser indoors on a level counter top.
LEG OPTION
Unpack the 4 legs and install them into the threaded holes provided in the bottom of the unit. The installer
must provide flexibility in the product and utility lines to permit shifting the position of the dispenser suffi-
ciently to clean the area beneath it.
NOTE: before installing legs, the plastic plugs must be removed by pushing the center in and
removing plug.
COUNTER MOUNTING
The ice dispenser must be sealed to the counter. The template drawing indicates openings which must be
cut in the counter. Locate the desired position for the dispenser, then mark the outline dimensions on the
counter using the template drawings. Cut openings in counter.
Apply a continuous bead of National Sanitation Foundation (NSF) listed silastic sealant (Dow 732 or equal)
approximately 1/4? inside of the unit outline dimensions and around all openings. Then position the unit on
the counter within the outline dimensions. All excess sealant must be wiped away immediately.
2. Utilities: DB150S-M Model: The electrical power cord, air/CO
2
line and dispenser drain (3/4 FPT) are
located at the rear of the unit.
DB150S-BM Models: All utilities are routed out the bottom of the unit. See “Mounting Template”
on page 6 for locating the required clearance holes in the counter for these utility lines.
3. Connect the drain tube to an open drain. For DB150 models, the drain line size must be 3/4? IPS (or equal)
and must continuously pitch downward away from the unit and contain no “traps” or improper drainage will
result.
DRAIN LINE
STAINLESS STEEL ELBOW
DRAIN TUBING PROVIDED
WITH DISPENSER
DISPENSER BOTTOM
FIGURE 1. SINK DRAIN ASSEMBLY --B, --BC MODELS
A. Use tube, clamp and insulation provided to assembly drain.
B. To assure proper drainage, do not allow “trap” to form in drain line. Be sure drain line runs flat with
bottom of dispenser (See Figure 1)