Specifications
InformationregardingModelNumber, Serial
Number,Ampacity and MaximumFuse Size are
located on thenameplateof theicemachine.The
modelnumber,serialnumberand refrigerant
charge arealsolistedon
theserialnumberplate
justbehindthefront
panel.
Ifrecharging,always
usethechargelisted on
theicemachine.
Specifications:
The SLE400Rwillstack
ontoa varietyofice
storage bins,see sales
literatureforproperice
storage bin.
*Minimum CircuitAmpacityisused todetermine
wiresizeand type pertheNationalElectricCode.
Note:Donot connectthisrefrigerationsystemto a
usedcondensercircuit.Onlythecondenserand
line setspecified forthismachine may be used.
SLE400R Back View
Water
Inlet
Drain
Electrical
Inlet
DischargeLine
Fitting(
3
⁄
8
"OD)
Liquid Line
Fitting(
1
⁄
4
"OD)
ModelNumber Dimensions
W"x D" xH"
Condenser
Type
Basic
Electrical
Minimum
Circuit
Ampacity*
Maximum
Fuse Size(or
HACR circuit
breakers)
Refrigerant
Charge.
R-404A
SLE400RS-32A 22x23x20 RemoteAir 208-230/60/1 16.5 20 136ounces
Nameplate
SLE400RCabinet
Serial Number
Plate
Condenser:
•RCE400-32A
LineSet:
•RTESL25or RTESL40
SLE400R
January1995
Page 2