Scotsman CME1002R Especificaciones Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
SERVICE SPECIFICATIONS: CME865R
The following numbers may be used as a
guideline. There will be some variation from unit to
unit. Numbers = (Condenser/Cabinet/Water).
Typical Total Amps
5 minutes into freeze: 8.4
End of harvest: 11.8
Refrigerant Charge
288 oz of R-404A
High Pressure Cut Out
450
Typical Harvest Ice Weight
8.2 - 8.5 lb.
Pump Down Pressure Switch
Closes at 35 PSIG
Opens at 15 PSIG
Cube Size Control
Cut In adjustable between 12.5
o
F. and 24
o
F.
0/70/55 90/90/70 120/110/100
Typical Cycle Time 14 - 15 minutes 15 - 16 minutes 26 - 27 minutes
Harvest Time (2
2
3
min. standard) 3
1
4
minutes needed
2 minutes 2 minutes
Typical Freeze Cycle Low Side
Pressure (end of cycle)
26 PSIG 28 PSIG 35 PSIG
Typical Freeze Cycle Discharge
Pressure (end of cycle)
210 PSIG 235 PSIG 330 PSIG
Typical Harvest Cycle Low Side
Pressure (peak)
75 PSIG 100 PSIG 160 PSIG
Typical Harvest Cycle Discharge
Pressure (min)
150 PSIG 200 PSIG 292 PSIG
CME865R & CME1002R
September, 1994
Page 18
Vista de pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 31 32

Comentarios a estos manuales

Sin comentarios