Scotsman Ice Systems are designed
and manufactured with the highest
regard for safety and performance.
They meet or exceed the standards of
U.L., N.S.F., and C.S.A.
Scotsman assumes no liability or
responsibility of any kind for products
manufactured by Scotsman that have
been altered in any way, including the
use of any parts and/or other
components not specifically approved
by Scotsman.
Scotsman reserves the right to make
design changes and/or improvements
at any time. Specifications and
designs are subject to change without
notice.
FOR THE INSTALLER
The MCM1462R will fit Scotsman ice storage bin
MDB900 and is stackable with stacking kit
KSMCM48.
Either a Scotsman remote condenser or a Mac 6
condensing system are required to for this ice
system.
Other items required:
Precharged tubing kit
Power cord and receptical
Condenser power cord
If stacking two units, a stacking kit
If using one unit, a caster kit for the bin.
Model Number Dimensions
(without bin)
W" x D" x H"
Basic
Electrical
Refrigerant
Type
Minimum
Circuit
Ampacity*
Maximum
Fuse Size
Refrigerant
Charge**
R-22
Condenser
Type
MCM1462RS-3A
48 x 24
3
8
x 27
1
2
208-230/60/3 R-22 20.5 30 256 oz. Remote Air
* Minimum Circuit Ampacity is used to determine wire size and type per the National Electric Code.
** The unit is shipped with the full charge in the receiver. For re-charging purposes, if the nameplate charge
is different than this number, go by the nameplate.
Use Scotsman remote condenser RC1422, or Mac 6. Use precharged tubing kit MLS2255 (55’) or
MLS2265 (65’) or MLS2275 (75’).
Power Cord is kit number: MPC
Caster Kit is number: KBC9
This ice system (except remote condenser) is designed to be installed indoors, in a controlled environment.
MINIMUM MAXIMUM
Air Temperature 50
0
F. 100
0
F.
Water Temperature 40
0
F. 100
0
F.
Water Pressure 20 psi 80 psi
Voltage -5% +10%
Back View
MCM1462R
April, 1993
Page 2