ACM 126
Standard: Medium cube. Option: Small, Large cube.
Dimensions (mm): H 930 (legs + 120) x W 680 x D 600
Max. production/24hrs: 71 Kg 3550 Cubes
Bin capacity: 39 Kg
Weight: 75 Kg
Water consumption: 190 Litres (AS) @15°C
750 Litres (WS) @15°C
Water Filter: HF20-S
Electricity consumption: 14 kwh
Circuit rating 13 Amps
Voltage 230/50/1*
ACM 176
Standard: Medium cube. Option: Small, Large cube.
Dimensions (mm): H 1000 (legs + 120) x W 680 x D 600
Max. production/24hrs: 84 Kg 4200 Cubes
Bin capacity: 48 Kg
Weight: 80 Kg
Water consumption: 150 Litres (AS) @15°C
1050 Litres (WS) @15°C
Water Filter: HF20-S
Electricity consumption: 15 kwh
Circuit rating 13 Amps
Voltage 230/50/1*
ACM 206
Standard: Medium cube. Option: Small, Large cube.
Dimensions (mm): H 780 (legs + 80) x W 1250 x D 620
Max. production/24hrs: 130 Kg 6500 Cubes
Bin capacity: 50 Kg
Weight: 82 Kg
Water consumption: 288 Litres (AS) @15°C
2496 Litres (WS) @15°C
Water Filter: HF40-S
Electricity consumption: 17.3 kwh
Circuit rating 13 Amps
Voltage 230/50/1*
ACM 226
Standard: Medium cube. Option: Small, Large cube.
Dimensions (mm):H 1006 (legs + 120) x W 1078 x D 715
Max. production/24hrs: 145 Kg 7250 Cubes
Bin capacity: 70 Kg
Weight: 96 Kg
Water consumption: 336 Litres (AS) @15°C
3336 Litres (WS) @15°C
Water Filter: HF40-S
Electricity consumption: 24.2 kwh
Circuit rating 13 Amps
Voltage 230/50/1*
Air Cooled (AS) Water Cooled (WS)
*Other voltages available, please call to discuss