SYMPTON POSSIBLE CAUSE SUGGEST CORRECTION
Irregular cubes size & some Some jets plugged remove spray bar & jet bearing
cloudy and clean them
Shortage of water See shortage of water
Unit not level Level as required
Spray bar not rotating and clean them
Remove spray bar & jet bearing
Cubes too large Freezing cycle too long Review setting of DIP SWITCH keys
Inoperative evaporator sensor Replace sensor
Decrease ice capacity Inefficient compressor Replace
Leaky water valve repair or replace
Non-condensable gas in system Recover refrig. add new gas &
drier, after evacuating the system
Poor air circulation or excessive Relocate the unit or provide for
hot location (Red-alarm LED glows) more ventilation
Overcharge of refrigerant Correct the charge. Purge off
slowly
Capillary tube partially restricted Recover refrig. add new gas &
drier, after evacuating the system
Hot gas solenoid valve leaking Replace valve
Undercharge of refrigerant Charge to data plate indication
Spray bar not rotating Remove spray bar & jet bearing
and clean them
Discharge head pressure too high See incorrect discharge pressure
Poor harvest Too short defrost time Check & adjust DIP SWITCH
keys 5-6-7
Restriction in incoming water line Check water valve strainer and flow
control. If necessary enlarge the
flow control orifice
Water inlet valve not opening Valve coil with open winding
Replace valve
Hot gas valve orifice restricted replace hpt gas valve assy
Air vented holes in mold cups plugged Clean out holes
Discharge head pressure too low See incorrect discharge pressure
Unit won't harvest Inoperative P.C. Board Replace P.C. Board
Hot gas valve not opening Valve coil with open winding
Replace valve
Water solenoid valve not opening Valve coil with open winding
Replace valve
Incorrect discharge pressure inoperative condenser sensor replace sensor
Inoperative P.C. Board replace P.C. Board
Water regulating valve misadjusted Adjust its setting stem
Excessive water in unit base Water tubing leaking Check. Tighten or replace.
SERVICE DIAGNOSIS