Operational Characteristics: CME656R
Cycle Times (minutes):
System Pressures (PSIG):
Refrigerant Charge
CME656R uses 232 ounces when
connected to ERC201, or 280 ounces when
connected to ERC402. All R-404A.
Typical Compressor Amp, single phase
9 - 13 freeze
13 - 18 harvest
Typical Compressor Amps, three phase
6 - 7 freeze
9 - 10 harvest
Typical Harvest Ice Weight
6.5 - 7 lb.
CME506R, 656R, 806R: AutoIQ Cubers
January 2000
Page 33
0
o
F. condenser air 70
o
F. indoor air,
55
o
F. water
90
o
F. condenser air 90
o
F. indoor
air, 70
o
F. water
Freeze 13 - 15 15 - 17
Harvest 3 1:30
0
o
F. condenser air 70
o
F. indoor air,
55
o
F. water
90
o
F. condenser air 90
o
F. indoor
air, 70
o
F. water
Suction: End of Freeze 24 - 27 27 - 29
Suction: Peak in Harvest 85 - 105 100 - 110
Discharge: 5 minutes into Freeze 240 - 260 265 - 295
Discharge: Minimum in Harvest 190 - 210 225 - 230