SERVICE SPECIFICATIONS: CME865W
The following numbers may be used as a
guideline. There will be some variation from unit to
unit. Numbers = (Cabinet/Water).
Typical Total Amps
••5 minutes into freeze: 8.7
••End of harvest: 10.6
Refrigerant Charge
••36 oz of R-404A
High Pressure Cut Out
••400
Typical Harvest Ice Weight
•• 8.2 - 8.5 lb.
Cube Size Control
••Cut In adjustable between 12.5
o
F. and 24
o
F.
70/50 90/70 110/100
Typical Cycle Time 14 - 15 minutes 16 - 17 minutes 23 - 24 minutes
Harvest Time (2
2
⁄
3
min. standard) 2
2
⁄
3
minutes needed
2.5 minutes 2 minutes
Typical Freeze Cycle Low Side
Pressure (end of cycle)
28 PSIG 29 PSIG 29 PSIG
Typical Freeze Cycle Discharge
Pressure (end of cycle)
245 PSIG 245 PSIG 245 PSIG
Typical Harvest Cycle Low Side
Pressure (peak)
90 PSIG 100 PSIG 144 PSIG
Typical Harvest Cycle Discharge
Pressure (min)
180 PSIG 190 PSIG 215 PSIG
CME865W & CME1002W
December, 1994
Page 16
Comentarios a estos manuales