Vista de pagina 1
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of U.L., N.S.F., and C.U.L.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
FOR THE INSTALLER
These machines will fit the following Scotsman ice
storage bins:
BH900
BH1000 (with bin top KBT21)
BH1360
and will stack onto the following ice machines:
CME1402 or CME1202 (use KSCMS48)
MCM1462 or CMS1402B or CMS1202B (with
stacking kit KSCMS48)
A remote condenser and precharged tubing kit are
required to assemble this ice system.
The normal finish for the machine is enamel
sandalwood. An optional stainless steel panel kit
(SPKCMS48) can be field installed. It contains a
stainless steel top, left side panel, an overlay right
side panel, and front panels.
Model Number Dimensions
(without bin)
W" x D" x H"
Basic
Electrical
Minimum
Circuit
Ampacity*
Maximum
Fuse
Size+
Refrigerant
Charge**
R-404A
Condenser
Type
CME1402RE-3A
48 x 24
3
8
x 27
1
2
208-230/60/3 15.5 20 336 oz. Remote Air
CME1402RE-32A
48 x 24
3
8
x 27
1
2
208-230/60/1 22.9 30 336 oz. Remote Air
CME1202RE-3A
48 x 24
3
8
x 27
1
2
208-230/60/3 14.4 20 336 oz. Remote Air
CME1202RE-32A
48 x 24
3
8
x 27
1
2
208-230/60/1 20.9 30 336 oz. Remote Air
CME1202RE-6A
48 x 24
3
8
x 27
1
2
230/50/1 336 oz. Remote Air
* Minimum Circuit Ampacity is used to determine wire size and type per the National Electric Code.
+ Or HACR type circuit breakers.
** The unit is shipped with the charge in the receiver and, beginning with May 1996 production, 112 oz in
the Scotsman ERC401 condenser. For re-charging purposes, see the table below.
Use Scotsman remote condenser RCE1401 or ERC401. Use precharged tubing kit RTE25 (25’) or RTE40
(40").
Note: This refrigeration system may NOT be connected to a condenser circuit that had been used
in a R-12, R-22 or R-502 system. Doing so will void the refrigeration system warranty.
This ice system (except remote condenser) is designed to be installed indoors, in a controlled environment.
MINIMUM MAXIMUM
Air Temperature 50
0
F. 100
0
F.
Water Temperature 40
0
F. 100
0
F.
Water Pressure 20 psi 80 psi
Voltage -5% +10%
Condenser Model Total System Charge
ERC401 448 oz
RCE1401 448 oz
MAC 7G 336 oz
Charging Table