Scotsman C1448R Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 128
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
Controller Information
Machine Indicator Lights
Power
Status
Water
Clean
Code Display
Main codes - automatically displayed
F .......Freeze Cycle
F flashes . . Freeze Cycle is Pending
H .......Harvest Cycle
H flashes . . Manual Harvest
b .......BinisFull
C .......Clean Cycle
L .......Board Locked
d .......Test Mode
O .......Off
E .......Self Test Failed
1 flashes . . Max Freeze - Retrying
1 .......MaxFreeze Time Shut Down
2 flashes . . Max Harvest - Retrying
2 .......MaxHarvest Time Shut Down
3 .......Slow Water Fill
4 .......High Discharge Temp
5 .......Sump Temp Sensor Failure
7 .......Discharge Temp Sensor Failure
8 flashes . . Short Freeze - Retrying
8 .......Short Freeze - Thin ice
Setting Codes - requires push button sequence
Water Purge Settings
A, 1, 2, 3, 4, 5
De-Scale notification
- see table to the right
November 2008 Page 22
Change De-Scale Notification Interval -
This feature is accessible only from
standby (Status Light Off).
1. Press and hold harvest button for 3
seconds.
This starts the Time to Clean
Adjustment Mode and displays the
current time to clean setting.
2. Press the clean button repeatedly to
cycle through the 4 settings:
Prior Effective 11/6/08
3 months 1 year
4 months 0 or disabled
5 months 4 months
6 months (default) 6 months (default)
3. Push Off to confirm the selection.
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 127 128

Comentarios a estos manuales

Sin comentarios