INTRODUCTION
To the owner or user: The service manual
you are reading is intended to provide you,
and the maintenance or service technician,
with the information needed to install, start up,
clean, maintain, and service this ice system.
The NM650R is a remote condenser modular
ice system that fits a variety of Scotsman
storage bins. It features: front service for the
freezer, gearmotor, control box, water
reservoir, and bin control; an electronic circuit
for monitoring ice and water level; a
thermostatic expansion valve; and R-502 as
the refrigerant.
TABLE OF CONTENTS
For the Installer
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Remote Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
For the Plumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
For the Electrician . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Final Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Component Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Maintenance & Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Service Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Removal and Replacement
Water Reservoir & Bin Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Thrust Bearing & Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Auger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Water Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Evaporator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Gearmotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Circuit Board Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Parts Lists and Wiring Diagrams are located in the center of this manual, printed on yellow
paper.
NM650R
December, 1988
Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 37 38

Indice de contenidos

Pagina 1 - INTRODUCTION

INTRODUCTIONTo the owner or user: The service manualyou are reading is intended to provide you,and the maintenance or service technician,with the inf

Pagina 2 - FOR THE INSTALLER

FOR THE ELECTRICIANCONFORM TO ALL APPLICABLE CODESThe electrical power to the unit is suppliedthrough the junction box at the rear of themachine.Check

Pagina 3

///////////////////////////WARNING/////////////////////////////Do all wiring with the electrical powerdisconnected.///////////////////////////////////

Pagina 4

6. Check phasing of the electrical circuit asfollows:A. The phasing of the wiring MUST now bechecked, as incorrect phasing will result in afailure o

Pagina 5

FOR THE INSTALLER: Completed InstallationROOF CUT-AWAYINSULATEDPRECHARGEDREFRIGERANTTUBINGA typical installation should generally appearas illustrated

Pagina 6

FOR THE INSTALLER: Final Check List1. Is the ice system installedindoors in a location wherethe air and watertemperatures are controlled,and where the

Pagina 7

START UPPre-Start Inspection1. Remove the front, left, and right sideservice panels.2. Check that any styrofoam shipping blockshave been removed.3. In

Pagina 8 - FOR THE INSTALLER: Location

COMPONENT DESCRIPTIONControl Box: Contains the electrical controlsthat operate the machine.High Pressure Cut Out: A manual resetswitch sensing the h

Pagina 9 - FOR THE PLUMBER

COMPONENT DESCRIPTION: Control BoxContactor: A definite purpose contactorconnecting the compressor and the remotecondenser fan motor to the power sup

Pagina 10 - FOR THE ELECTRICIAN

Refer the wiring diagram as needed.If the machine is switched off at the masterswitch, but is otherwise ready to go, switchingthe master switch to ON

Pagina 11 - December, 1988

OPERATION: WaterWater enters the machine through the 3/8"male flare at the rear of the cabinet, goes tothe water reservoir which it enters throug

Pagina 12

FOR THE INSTALLERThe NM650R is designed to fit the followingScotsman storage bins:••B590 and extentions, with bin top KBT18.••BH800 using bin top KBT1

Pagina 13

OPERATION: RefrigerationBeginning at the compressor, the refrigerant502 is compressed into a high temperaturegas. The discharge line directs this gas

Pagina 14

OPERATION: RefrigerationLow Condensing TemperatureThe refrigeration system under low condenserair temperatures is much the same as it isunder higher t

Pagina 15 - START UP

OPERATION: RefrigerationPUMP DOWNDuring the pump down cycle (usually initiatedby the circuit board de-energizing the liquidline valve) the discharge g

Pagina 16 - COMPONENT DESCRIPTION

MAINTENANCE AND CLEANING//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Pagina 17

/////////////////////////////WARNING///////////////////////////Disconnect electrical power before beginning.//////////////////////////////////////////

Pagina 18 - ELECTRICAL SEQUENCE

MAINTENANCE AND CLEANINGIn some areas the water supply to theicemaker will have a great deal of minerals init, and that will result in ann evaporator

Pagina 19 - OPERATION: Water

SERVICE DIAGNOSIS: Condition - No Ice Being ProducedSTATUS: NOTHING OPERATESA. Check: Voltage to the unit, restore it if there is none. Compare to the

Pagina 20 - OPERATION: Refrigeration

G. Check: The gear motor, if it will not run, the compressor will not run. If no power to it: Check:the indicator lights on the circuit board, the bi

Pagina 21

SERVICE DIAGNOSIS: Condition - No Ice Being ProducedSTATUS: GEARMOTOR OPERATES, COMPRESSOR DOES NOTA. Check the pump down control switch.1. This press

Pagina 22

SERVICE DIAGNOSIS: Condition - Low Ice ProductionSTATUS: EVERYTHING IS OPERATINGA. Check the condenser for dirt. Clean as required. Check the head pre

Pagina 23 - MAINTENANCE AND CLEANING

FOR THE INSTALLERInstallation Limitations:This ice system is designed to be installedindoors, in a controlled environment:Min MaxAir Temperature 500F

Pagina 24

WATER RESERVOIR1. Shut off the water supply to the icemaker.2. Remove front panel and reservoir cover.3. To remove float only, pry the mountingflanges

Pagina 25

REMOVAL AND REPLACEMENT: Bearing And BreakerNote: Removal of the auger, water seal,evaporator and gearmotor must begin at thetop of the assembly.To Re

Pagina 26 - NOTHING OPERATES

To Remove the Auger:Turn off the water to the machine, and unclipthe evaporator drain hose, pull it down anddrain the evaporator into the bin or a con

Pagina 27

To Remove the Water Seal: (Assuming all steps to remove the auger havebeen performed.)1. The gearmotor/evaporator assembly willhave to be pulled away

Pagina 28 - STATUS:

1. Discharge the refrigerant from the icemaker.2. Unsweat the refrigerant connections: a) At the thermostatic expansion valve outlet./////////////////

Pagina 29 - EVERYTHING IS OPERATING

OUTPUT GEAR,OUTPUT SHAFT,AND BEARINGSGASKETGEARCASEDRIVE MOTORBEARINGSEALWATER SHEDSEALREMOVAL AND REPLACEMENT: Gearmotor Assembly////////////////////

Pagina 30

1. Remove the electrical wires from the geardrive motor.2. Unscrew the 4 cap screws holding thegearmotor to the gearmotor plate.3. Remove the gearmoto

Pagina 31

CIRCUIT BOARD TESTINGINSTRUCTIONS FOR USING TESTER MODEL FC1 (Optional, order part no. A33942-001)(These instructions assume that the unit will not r

Pagina 32

CIRCUIT BOARD TESTINGWater Level1. Unplug “water sen” connector from controlboard.2. Plug “water sen” connector from Scotsmantester into circuit boa

Pagina 33 - REMOVAL OF THE WATER SEAL

REMOTE CONDENSER SPECIFICATIONS22"27.81"19.86"5.75"1/2" MALE QUICK CONNECTCOUPLING FOR USE WITHRT625 OR RT640PRECHARGED LINE

Pagina 34

FOR THE INSTALLERLocationAfter uncrating and inspection, the unit isready for installation. It is important that themachine be installed in a location

Pagina 35

FOR THE INSTALLER: Remote CondenserLocationLimited to a 40 foot or a 25 foot length ofprecharged refrigerant tubing connecting theicemaker to the remo

Pagina 36 - If there was no

COUPLING INSTRUCTIONS/////////////////////////////CAUTION/////////////////////////////The couplings on the sets of precharged linesare self sealing wh

Pagina 37 - CIRCUIT BOARD TESTING

FOR THE INSTALLER: LocationTWO UNITS ON ONECONDENSERREMOTECONDENSEREXCESSPRECHARGEDTUBING INSIDEBUIDLINGICEMAKERSSERVICEACCESSSERVICE ACCESSSIDE AND

Pagina 38

FOR THE PLUMBERCONFORM TO ALL APPLICABLE CODESWater InletThe recommended water supply iscold water. Use 3/8" O.D. coppertubing, connect to the 3