OPERATION: Water
Water enters the machine through the 3/8" male
flare at the rear of the cabinet, goes to the water
reservoir which it enters through the float valve.
The water them goes out the bottom of the
reservoir tank to the bottom of the evaporator.
Reservoir overflow or evaporator condensation is
routed to the drain.
RESERVOIR
DRAIN TUBE
WATER LEVEL
WATER
INLET
DRAIN
Water Level: The correct water level should be
checked when the machine is making ice. Locate the
water level in the reservoir and compare it to the
horizontal line molded into the side of the reservoir.
The correct level should be between
1
8
" above and
1
4
" below the line. If needed, bend the float arm up or
down to adjust the water level.