Scotsman FM2400R Manual de servicio Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
Water Inlet
The recommended water supply is
cold water. Use 3/8" O.D. copper
tubing, connect to the 3/8" male
flare at the back of the cabinet.
Install a hand valve near the
machine to control the water
supply.
Drains
There is one 3/4" FPT drain at the
back of the cabinet, the drain line
is of the gravity type, and 1/4 inch
per foot fall is an acceptable pitch
for the drain tubing. There should
be a vent at the highest point of
the drain line, and the ideal drain
receptacle would be a trapped and
vented floor drain. Use only 3/4"
rigid tubing.
Storage Bin: A separate gravity
type drain needs to be run.
Insulation of this drain line is
recommended.
FLOOR DRAIN
VENT BIN DRAIN
3/4" FPT
VENT
ICEMAKER
DRAIN,
3/4" FPT
WATER INLET
3/8" MALE
FLARE
FIELD
SUPPLIED
WATER FILTER
HAND SHUT
OFF VALVE
CONNECT TO
COLD WATER
FM2400R
December, 1988
Page 9
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 35 36

Comentarios a estos manuales

Sin comentarios