August 2013
Page 3
Service Manual for Models CU0415, CU0715 and CU0920
Pre-Installation
This appliance is intended to be used in commercial
applications including:
• Restaurant kitchens
• Bars
• Hotels
Dimensions and Electrical:
Location:
Theunitcanbebuiltintoacabinetastheairow
is in and out the front. The front of the machine
must not be blocked. Certain maintenance or
repairprocedureswillrequireremovalofthetop,
back and side panels, so plan ahead for service and
maintenance needs.
Spacing:
Noadditionalspacingisrequiredatthetoporsides.
However,suggestedminimumsideclearancefor
installation is 1/8 inch or 3 mm and suggested
minimum top clearance is 1/4 inch or 7 mm.
Allow4inches(100mm)minimumspaceattheback
for the utility connections. Do not block louvers at the
front of the cabinet.
Unpacking and setup
Remove all shipping and packing materials that may
be in the ice storage bin.
Theunitcanbeinstalledwithorwithoutlegs.The
cabinetisequippedwithsmallbumpersonthebase
toallowplacementwithoutlegs.Anoptionaloor
mountingkitisalsoavailabletollthegapbetween
themachineandoorifnotusinglegs.Ifusinglegs,
carefully tip the machine and install the legs by
screwingthemintothelegsocketsinthebottomof
the machine. For reference, the thread size is 5/8 –
11.Ifthemachinehasbeentippedontoitssideor
backallow1hourbeforestartingtheunitfortheoilin
the refrigeration system to return to the compressor.
Place the machine in its intended location and level it
fronttobackandlefttoright.Ifusinglegs,adjusttheir
feet in and out to level the cabinet.
Iflegsarenotusedthebottomedgesofthecabinet
mustbesealedtotheoor.
Ifbuiltintoacabinet,theadjacentcabinetwallswill
provide the means for containment. There are no
means for attachment to the cabinet.
Be sure to remove the plastic covering the exterior panels,
ifleftonitwillbemuchhardertoremovelater.
Model Electrical
(volts/Hz/Phase
Width
(in/cm)
Depth
(in/cm)
Height(w/olegs)
(in/cm)
Total Load
Amps
CU0415MA-1A 115/60/1 15 / 38 23.7 / 60.3 31.94 / 81.1 8
CU0715MA-1A 115/60/1 15 / 38 23.7 / 60.3 31.94 / 81.1 8
CU0920MA-1A 115/60/1 20 / 51 23.7 / 60.3 31.94 / 81.1 8