Scotsman C1848R Manual de usuario Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 26
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
Drains
All models require drain tubing to be attached to
them. There is a single ¾” FPT drain fitting in the
back of the cabinet.
Install new tubing when replacing a prior ice
machine, as the tubing will have been sized for the
old model and might not be correct for this one.
1. Connect water supply to water inlet fittings.
2. Connect drain tubing to drain fitting.
3. Route the drain tubing to building drain. Follow
local codes for air gap.
4. Use rigid drain tubes and route them
separately – do not Tee into the bin’s drain.
Vent the reservoir drain. A vertical vent at the back
of the drain, extended about 8 – 10” will allow the
gravity drain to empty and also keep any surges
during draining from discharging water.
Horizontal runs of drain tubing need a ¼” per fall
per foot of run for proper draining.
Follow all applicable codes.
November 2006
Page 13
C1448, C1848, C2148
Remote Condenser Models - User Manual
Water Supply and Drain Connections
Water Inlet
Connection
Potable Water
Supply
Reservoir
Drain, Venting
Required
Optional Water
Filters
Floor Drain
Vista de pagina 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 25 26