INTRODUCTIONTo the owner or user: The service manual you arereading is intended to provide you, and themaintenance or service technician, with theinfo
COMPONENT DESCRIPTIONEvaporator: A refrigerated vertical tube filled withwater and containing a water seal and auger.Auger: A solid stainless steel
ELECTRICAL SEQUENCERefer the wiring diagram as needed.If the machine is switched off at the master switch,but is otherwise ready to go, switching the
OPERATION: WaterWater enters the machine through the 3/8" maleflare at the rear of the cabinet, goes to a strainerand then to the water reservoir
OPERATION: RefrigerationBeginning at the compressor, the refrigerant iscompressed into a high temperature gas. Thedischarge line directs this gas to
TECHNICAL CHARACTERISTICSTypical Low Side Pressure••32 - 34 PSIG, less in cooler ambients, greater in hot ambientsTypical Discharge Pressure••200 - 2
MAINTENANCE AND CLEANINGA Scotsman Ice System represents a sizable investment of time and money in any company’s business. Inorder to receive the bes
1. The bin control uses devices that sense light,therefore they must be kept clean enough so thatthey can "see". At least twice a year, remo
In some areas, the water supply to the ice makerwill contain a high concentration of minerals, andthat will result in an evaporator and augerbecoming
SERVICE DIAGNOSIS: Condition - No Ice Being ProducedSTATUS: NOTHING OPERATESA. Check: Voltage to the unit, restore it if there is none. Compare to the
SERVICE DIAGNOSIS: Condition - No Ice Being ProducedSTATUS: NOTHING OPERATESG. Check: The gear motor, if it will not run, the compressor will not run.
FOR THE INSTALLERInstallation Limitations:This ice system is designed to be installed indoors,in a controlled environment:Min. Max.Air Temperature 50
STATUS: GEARMOTOR OPERATES, COMPRESSOR DOES NOTA. Check the compressor relay.The relay is on the circuit board, if it does not supply power to the con
SERVICE DIAGNOSIS: Condition - Low Ice ProductionSTATUS: EVERYTHING IS OPERATINGA. Check the air cooled condenser for dirt. Clean as required. Check
WATER RESERVOIR1. Shut off the water supply to the icemaker.2. Remove front panel and reservoir cover.3. Disconnect water inlet line from float valve.
REMOVAL AND REPLACEMENT: Bearing And BreakerNote: Removal of the auger, water seal,evaporator and gearmotor must begin at the top ofthe assembly.To Re
To Remove the Auger:Turn off the water to the machine, and unclip theevaporator drain hose, pull it down and drain theevaporator into the bin or a con
To Remove the WaterSeal: (Assuming all steps toremove the auger havebeen performed.)1. Thegearmotor/evaporatorassembly will have tobe exposed.2. Remov
To Replace the Evaporator:(Assuming all the steps for removal of the thrustbearing, breaker, auger, and water seal have beenperformed.)1. Recover the
ICE SWEEPAUGEREVAPORATORBREAKERBEARINGWATERSEALRETAININGRINGDRIP PANGASKETWATER SHEDGEARMOTORASSEMBLYSEAL(S)O-RINGCAP SCREWO-RINGWATERSHEDLIP SEALBREA
To Remove and Repair the GearmotorAssembly:(Assuming that the procedures through removal ofthe water seal have been performed.)1. Remove the electrica
REFRIGERATION SERVICE: R-404ATHIS ICE MACHINE USES R-404A (HP62)REFRIGERANT AND POLYOLESTERCOMPRESSOR OIL.DO NOT USE MINERAL OIL IN THISREFRIGERATION
LocationAfter uncrating the machine, and inspecting it forfreight damage, the unit is ready for installation. It is important that the machine be inst
REFRIGERATION SERVICEGeneral Information:Work on the refrigeration system should only bedone when it is certain that the system needsrepair. ••Refrain
CIRCUIT BOARD TESTINGINSTRUCTIONS FOR USING TESTER (Optional,order part no. A33942-001)(These instructions assume that the unit will not run,and prior
CIRCUIT BOARD TESTINGWater Level1. Unplug “water sen” connector from controlboard.2. Plug “water sen” connector from Scotsmantester into circuit boa
FOR THE PLUMBERCONFORM TO ALL APPLICABLE CODESWater InletAir Cooled Models: The recommendedwater supply is clean, cold water. Use3/8" O.D. coppe
FOR THE ELECTRICIANCONFORM TO ALL APPLICABLE CODESThe electrical power to the unit is supplied throughthe junction box at the rear of the machine.Chec
FOR THE INSTALLERFinal Check List1. Is the ice system installed indoors in a locationwhere the air and water temperatures arecontrolled, and where the
START UPPre-Start Inspection1. Remove the front panels.2. Check that the styrofoam shipping blocks havebeen removed.3. Inspect the interior of the ma
COMPONENT DESCRIPTIONControl Box: Contains the electrical controls thatoperate the machine.High Pressure Cut Out Switch: A manual resetswitch sensing
COMPONENT DESCRIPTION: Control BoxContactor: A definite purpose contactorconnecting the compressor and the remotecondenser fan motor to the power su
Comentarios a estos manuales