Scotsman CME1002W Manual de servicio

Busca en linea o descarga Manual de servicio para Máquinas productoras de hielo Scotsman CME1002W. Scotsman CME1002W Service manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
INTRODUCTION
To the owner or user: This service manual is
intended to provide you and the maintenance or
service technician with the information needed to
install, start up, clean, maintain and service this
ice system.
Table of Contents
FOR THE INSTALLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
BACK VIEW OF CABINET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3
ERC401 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
FOR THE INSTALLER: Location & Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
FOR THE INSTALLER: Location & Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
FOR THE INSTALLER: Scotsman Remote Condenser . . . . . . . . . . . . . . . . . . . . . . page 7
FOR THE INSTALLER: Coupling Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
FOR THE ELECTRICIAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
FOR THE PLUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
FINAL CHECK LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
INITIAL START UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
FREEZING CYCLE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
HARVEST CYCLE - HOT GAS BYPASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
COMPONENT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 19
SYSTEM SPECIFICATIONS: CME1202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21
SYSTEM SPECIFICATIONS: CME1402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22
ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23
SERVICE DIAGNOSIS: Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24
SERVICE DIAGNOSIS: Electrical and/or Adjustments . . . . . . . . . . . . . . . . . . . . . . page 25
SERVICE DIAGNOSIS: Refrigeration and/or Mechanical . . . . . . . . . . . . . . . . . . . . . page 26
SERVICE DIAGNOSIS: Bin Ice Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . page 27
REMOVAL AND REPLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 28
REFRIGERATION SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 31
LIQUID CHARGING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 32
Parts Lists and Wiring Diagrams are located in
the center of this manual, printed on yellow
paper.
This manual was printed on recycled paper.
Keep this manual for future reference.
Note this symbol when it appears in the
manual. It indicates a potential hazard.
CME1202R & CME1402R
January 1995
Page 1
Vista de pagina 0
1 2 3 4 5 6 ... 39 40

Indice de contenidos

Pagina 1 - CME1202R & CME1402R

INTRODUCTIONTo the owner or user: This service manual isintended to provide you and the maintenance orservice technician with the information needed t

Pagina 2

FOR THE PLUMBERThe recommended water supply line is a 3/8-inchO.D. copper tubing with a minimum operatingpressure of 20 PSIG and a maximum of 80 PSIG.

Pagina 3

FINAL CHECK LIST1. Is the cabinet in a room where ambienttemperatures are within the minimum andmaximum temperatures specified?2. Is there clearance a

Pagina 4

INITIAL START UPBefore Start Up:1. Check that both the ICE-OFF-WASH rockerswitch and the COMPRESSOR ON-OFF toggleswitch are in the OFF position. 2. Sw

Pagina 5

INITIAL START UP9. Check operation of the freezing cycle: Ice willbegin to form from the top of the evaporatorsdown. After the first cycle, freezing t

Pagina 6

FREEZING CYCLE OPERATIONWater from the sump assembly is pumped to thewater distributor system at the top of eachevaporator plate. From the water distr

Pagina 7

HARVEST CYCLE - HOT GAS BYPASS When the timer switches the ice maker into theharvest cycle, high pressure, high temperature gasrefrigerant being disch

Pagina 8

COMPONENT DESCRIPTIONCube Size ControlThis reverse acting thermostat controls the lengthof the freezing cycle. It is sensing the temperatureof the suc

Pagina 9

COMPONENT DESCRIPTIONBin Level ControlThis electronic control uses sound waves tomeasure the distance between the bottom of theice machine and the top

Pagina 10

COMPONENT DESCRIPTIONWater Inlet Solenoid Valve The water inlet solenoid valve fills the sumpassembly with water and excess water overflowsout the sta

Pagina 11

CLEANINGA Scotsman Ice System represents a sizable investment of time and money in any company’s business. Inorder to receive the best return for tha

Pagina 12

Scotsman Ice Systems are designed andmanufactured with the highest regard for safetyand performance. They meet or exceed thestandards of U.L., N.S.F.

Pagina 13

CLEANINGRemote Condenser1. Shut off the ice machine.2. Remove dirt and debris that might be under thecondenser.3. Brush off the bottom of the condense

Pagina 14

SYSTEM SPECIFICATIONS: CME1202The following numbers are a guideline to field operation There will be some variation from unit to unit.The numbers head

Pagina 15

SYSTEM SPECIFICATIONS: CME1402The following numbers are a guideline to field operation. There will be some variation from unit to unit.The numbers hea

Pagina 16

ADJUSTMENTSAdjustment Of The Timer & Switch AssemblyOne complete revolution of the cam on the timertakes eight minutes. The harvest time set at th

Pagina 17

SERVICE DIAGNOSIS: WaterSYMPTOM POSSIBLE CAUSE PROBABLE FIXNo ice is made Inlet water valve will not open oris dirtyClean inlet screen, check coil,rep

Pagina 18

SERVICE DIAGNOSIS: Electrical and/or AdjustmentsSYMPTOM POSSIBLE CAUSE PROBABLE FIXMachine does not operate No power Reconnect powerHigh pressure cont

Pagina 19

SERVICE DIAGNOSIS: Refrigeration and/or MechanicalSYMPTOM POSSIBLE CAUSE PROBABLE FIXPoor harvest Hot gas valve does not open Check for power to the c

Pagina 20

CONDITION DETERMINE CAUSE PROBABLE CORRECTIONIce Machine does not run, ithas power to it, the highpressure control is closed,the on/off switch is set

Pagina 21

Sonar Sonar is Scotsman's ultrasonic device for measuring ice level and switching the ice machine on and off. It consists of a control board, t

Pagina 22

Sonar Service Diagnosis Step 1. Determine if it's a bin control problem.– Machine will not switch on  Reset high pressure cut out Jump the two

Pagina 23

BACK VIEW OF CABINETCME1202R & CME1402RJune 1996Page 3

Pagina 24

Sonar Service Diagnosis Step 2: If it is a sonar problem, check the board.– 12 volts to board.  If not, check the transformer.– When ice is called f

Pagina 25

Sonar Service Diagnosis Step 3. If the red light is NOT ON– Check the selector switch and harness.  Jump out the two outside pins on the board where

Pagina 26

Sonar Service Diagnosis Step 4: If the red light is not on, and jumping the two outside pins does not work, check the transducer.– CME1202 or CME1402

Pagina 27

Sonar Service Diagnosis Transducer Check– “Ticking” sound is normal– Examine the screen and face of the transducer. If the screen is dirty, clean it

Pagina 28

Sonar Service Diagnosis Transducer Check Switch power on and check the transducer against a hard, flat surface.  Try a NEW transducer, if that does

Pagina 29 - Sonar Service Diagnosis

Sonar Service DiagnosisCheck Transducer Resistor (green and white wires)- should be about 260-270 ohms.

Pagina 30

REMOVAL AND REPLACEMENTWater Distributor Tubes And Manifold Tubes To remove the water distributor tube and manifoldtube: 1. Remove the front panel. 2.

Pagina 31

Water Pump1. Remove front panel.2. Unplug water pump electrical connection.3. Drain water reservoir.4. Use corbin clamp pliers to loosen and slidecorb

Pagina 32

Thermostatic Expansion Valve1. Before replacing this valve, be certain that thevalve is the cause of the problem, and cannot beadjusted.2. Remove the

Pagina 33

VAPOR VAPOR TEMP. PRESS. TEMP. PRESS.(DEG F) (PSIG) DEG F) (PSIG)-20 17 70 146-18 18 72 150-16 20 74 155-14 21 76 161-1

Pagina 34

ERC401 SPECIFICATIONS23 13⁄16"19 7⁄8"ERC DimensionsABFG43 3⁄8"10 3⁄4"21 3⁄4"16 5⁄8"CME1202R & CME1402RJune 1996Page

Pagina 35

LIQUID CHARGING Instructions for R-404AIn preparation for charging, the low side hoseshould have a sight glass, and/or a restrictordevice (such as a &

Pagina 36

FOR THE INSTALLER: Location & AssemblyLocation:After uncrating and inspection, the unit is ready forinstallation. It is important that the machine

Pagina 37

FOR THE INSTALLER: Location & AssemblyStacking InstructionsA stacking kit, KSCMS48, is required tointerconnect the ice level controls, seal thefre

Pagina 38

FOR THE INSTALLER: Scotsman Remote CondenserLocate the condenser as near as possible to theinterior location of the ice maker. Location of the condens

Pagina 39

FOR THE INSTALLER: Coupling InstructionsCAUTIONThe couplings on the sets of precharged lines areself sealing when installed properly. Carefullyfollow

Pagina 40

FOR THE ELECTRICIAN See the ice machine nameplate for currentrequirements to determine wire and fuse size to beused for electrical hookup. When the cu

Comentarios a estos manuales